STATUTORY RULES OF NORTHERN IRELAND


2006 No. 355

BUILDING REGULATIONS

The Building (Amendment) Regulations (Northern Ireland) 2006

  Made 31st August 2006 
  Coming into operation 30th November 2006 

The Department of Finance and Personnel makes the following Regulations in exercise of the powers conferred by Articles 3, 5(1), (2) and (3) of, and paragraphs 2, 6, 9, 13, 15, 16, 17, 18, 19, 20, 21 and 22 of Schedule 1 to the Building Regulations (Northern Ireland) Order 1979[1] and now vested in it[2], and after consultation with the Building Regulations Advisory Committee[3] and such other bodies as appear to be representative of the interests concerned.

Citation and commencement
     1. These Regulations may be cited as the Building (Amendment) Regulations (Northern Ireland) 2006 and shall come into operation on 30th November 2006.

Interpretation
    
2. In these Regulations "the principal Regulations" means the Building Regulations (Northern Ireland) 2000[4].

Application of certain regulations to existing buildings
     3. Where it is proposed to execute building work in relation to any existing building with a total useful floor area greater than 1000 m² and that work consists of or includes—

regulations A10, A11, F2, F4 and F5 shall apply in relation to that building as they apply to any other building work after the commencement of these Regulations.

Transitional provisions
    
4. —(1) The principal Regulations shall continue to apply to—

as if the amendments effected by these Regulations had not been made.

    (2)

Amendment of the principal Regulations
    
5. The principal Regulations shall be amended as provided in regulations 6 to 15.

Amendment of Part A (Interpretation and general)
    
6. —(1) In paragraph (1) of regulation A2 (Interpretation)—

    (2) For paragraph (4)(b) of regulation A5 (Exemptions) there shall be substituted—

    (3) Under regulation A6 (Application to erection of buildings) there shall be substituted—

    (4) In regulation A7 (Application to alterations and extensions)—

    (5) In regulation A8 (Application to services and fittings)—

    (6) After regulation A8 there shall be inserted—

    (7) In regulation A9 (Application to material change of use)—

    (8) In regulation A10 (Giving of notices and deposit of plans)—

    (9) In regulation A11 (Notice of commencement and completion of certain stages of work)—

    (10) In regulation A16 (Exercise of power of dispensation or relaxation) the full stop at the end of Part D (Structure) shall be deleted and there shall thereafter be added—

Amendment of Part B (Materials and workmanship)
    
7. In paragraph (b) of regulation B2 (Fitness of materials and workmanship) the word "disabled" shall be deleted.

Substitution of Part F (Conservation of fuel and power)
    
8. For Part F (Conservation of fuel and power) there shall be substituted the Part set out in Schedule 1.

Substitution of Part L (Heat-producing appliances and liquefied petroleum gas installations)
    
9. For Part L (Heat-producing appliances and liquefied petroleum gas installations) there shall be substituted the Part set out in Schedule 2.

Substitution of Part R (Access and facilities for disabled people)
    
10. For Part R (Access and facilities for disabled people) there shall be substituted the Part set out in Schedule 3.

Amendment of Part V (Glazing)
    
11. In paragraph (4) of regulation V6 (Deemed-to-satisfy provisions for regulations V2, V3, V4 and V5) for the words "means of access to the building" there shall be substituted "means of access to the glazing".

Amendment of Schedule 1 (Classes of exempted buildings — Regulation A5(1))
    
12. In paragraph (n) of Class 8 (Other buildings) after the word "cesspool," there shall be inserted "fixed oil storage tank,".

Amendment of Schedule 2
    
13. —(1) Part A (Giving of notices and deposit of plans)—

    (2) Part B (Particulars to be given in a building notice)—

Amendment of Schedule 5 (Deemed-to-satisfy provisions)
    
14. —(1) In column (4) of Table E for the character "—" opposite the references in column (3) to "DFP Technical Booklet E: 2005" there shall be substituted "AMD 3".

    (2) For Table F there shall be substituted the Table set out in Schedule 4.

    (3) For Table H there shall be substituted the Table set out in Schedule 5.

    (4) For Table L there shall be substituted the Table set out in Schedule 6.

    (5) For Table R there shall be substituted the Table set out in Schedule 7.

    (6) For Table V there shall be substituted the Table set out in Schedule 8.

Amendment of Schedule 6
    
15. In Schedule 6 Table B. Other Publications, shall be deleted.



Sealed with the Official Seal of the Department of Finance and Personnel on


31st August 2006.

L.S.


B. Stuart
Assistant Secretary


SCHEDULE 1
Regulation 8


Part to be substituted for Part F (Conservation of fuel and power) of the principal Regulations




Part F

Conservation of fuel and power

     F1 Application and interpretation


    (1) Subject to paragraphs (2) and (3) this Part shall apply to any building and, where a building contains one or more dwellings, to each dwelling separately.

    (2) Regulations F2, F3 and F4 shall not apply to a building or part of a building other than a dwelling which—

    (3) Regulation F3 shall apply to any building or part of a building other than an extension to—

    (4) In this Part—

     F2 Conservation measures
Reasonable provision shall be made for the conservation of fuel and power in any building by—

     F3 Target carbon dioxide Emissions Rate


    (1) Without prejudice to the requirements of regulation F2, where a building is to be erected a Target carbon dioxide Emissions Rate (TER) for that building shall be calculated using a National Calculation Methodology.

    (2) The building shall be so designed and constructed as not to exceed its calculated Target carbon dioxide Emissions Rate (TER).

     F4 Provision of information
Reasonable provision shall be made to ensure that the owner of the building is provided with sufficient information about the building, the fixed building services and their maintenance requirements so that the building can be operated and maintained to maximise its design potential for the conservation of fuel and power.

     F5 Deemed-to-satisfy provisions for regulations F2, F3 and F4


    (1) The requirements of regulation F2 shall be deemed to be satisfied, in the case of a building specified in column (2) of Table F opposite the reference to that regulation, if—

    (2) The requirements of regulation F3 shall be deemed to be satisfied, in the case of a building specified in column (2) of Table F opposite the reference to that regulation, if—

    (3) The requirements of regulation F4 shall be deemed to be satisfied in the case of a building specified in column (2) of Table F opposite the reference to that regulation, if the information provided is in accordance with the relevant provisions of the publications specified opposite thereto in column (3), as amended by the publications specified opposite thereto in column (4).



SCHEDULE 2
Regulation 9


Part to be substituted for Part L (Heat-producing appliances and liquefied petroleum gas installations) of the principal Regulations




Part L

Combustion appliances and fuel storage systems

     L1 Application and interpretation


    (1) In this part—

    (2) Any provision in regulations L2, L3, L4, L5 and L8 which applies to a combustion appliance, shall also apply where solid fuel is intended to burn directly on a hearth without the installation of any appliance.

    (3) Regulation L6 shall only apply to a liquid fuel storage tank and connecting pipework located outside the building, which serves a fixed combustion appliance within the building and which is—

    (4) Regulation L7 shall only apply to a fixed oil storage tank, which serves a dwelling and to which any one of the following applies—

     L2 Air supply
A combustion appliance shall be so installed as to receive a sufficient supply of air to ensure the safe and efficient operation of the combustion appliance and any connected flue.

     L3 Discharge of products of combustion
A combustion appliance shall be so installed and any connected flue-pipe, flue or chimney shall be so constructed and installed as to ensure that the products of combustion are discharged to the external air without causing a hazard to the health of any person.

     L4 Protection of people and buildings


    (1) A combustion appliance shall be so installed and any connected flue-pipe, flue or chimney shall be so constructed and installed as to ensure that their use shall not cause—

    (2) A hearth or fireplace recess shall be so designed and constructed as to prevent damage to a building by heat or fire as a result of the operation of a combustion appliance installed in it or on it.

     L5 Provision of information
Where a hearth, fireplace, flue or chimney is provided or extended, a durable notice containing information on its performance capabilities shall be affixed to a suitable place in the building for the purpose of enabling a compatible combustion appliance to be safely connected to that hearth, fireplace, flue or chimney.

     L6 Protection of liquid fuel storage tanks
Reasonable provision shall be made to ensure that a liquid fuel storage tank and connecting pipework is so constructed and separated from adjacent buildings and the boundary of the premises as to reduce to a reasonable level the risk of the fuel contained inside it igniting in the event of a fire occurring in adjacent buildings or premises.

     L7 Protection against pollution
An oil storage tank and connecting pipework shall be so constructed and protected as to minimise the risk of an escape of oil causing pollution to the environment.

     L8 Prevention of smoke emission
A combustion appliance installed in a building for the purpose of heating or cooking, and which discharges its combustion products to the external air shall be capable of, or readily adaptable to, the burning of fuel smokelessly, unless it is—

     L9 Deemed-to-satisfy provisions for regulations L2, L3, L4, L5, L6 and L7


    (1) The requirements of regulations L2, L3 and L4 shall be deemed to be satisfied, in the case of a combustion appliance specified in column (2) of Part 1 of Table L opposite the reference to that regulation, if the combustion appliance and its associated construction is designed, constructed and installed in accordance with the relevant provisions of the publications specified opposite thereto in column (3), as amended by the publications specified opposite thereto in column (4).

    (2) The requirements of regulation L5 shall be deemed to be satisfied, in the case of the aspect specified in column (2) of part 2 of Table L opposite the reference to that regulation, if the information is provided in accordance with the notice template specified in the publication specified opposite thereto in column (3), as amended by the publications specified opposite thereto in column (4).

    (3) The requirements of regulation L6 shall be deemed to be satisfied, in the case of the aspect specified in column (2) of part 2 of Table L opposite the reference to the regulation, if the tank is sited or protected in accordance with the publications specified opposite thereto in column (3), as amended by the publications specified opposite thereto in column (4).

    (4) The requirements of regulation L7 shall be deemed to be satisfied, in the case of the aspect specified in column (2) of part 2 of Table L opposite the reference to regulation, if the tank is sited or protected in accordance with the publications specified opposite thereto in column (3), as amended by the publications specified opposite thereto in column (4).



SCHEDULE 3
Regulation 10


Part to be substituted for Part R (Access and facilities for disabled people) of the principal Regulations




Part R

Access to and use of buildings

     R1 Application and interpretation


    (1) Subject to paragraphs (2), (3) and (4) this Part shall apply to any building or part of a building.

    (2) This Part shall not apply to—

    (3) The requirements of regulation R3 shall not apply to—

    (4) The requirements of regulation R4 shall not apply to—

    (5) In this Part—

     R2 Access and use
Reasonable provision shall be made for people to have access to, into, within and to use a building and its facilities:

Provided that in a dwelling this requirement shall be limited to the entrance storey or, where that storey contains no habitable room, to the principal storey.

     R3 Access to extensions
Reasonable provision shall be made for independent access to an extension to a building.

     R4 Sanitary accommodation in extensions
Where sanitary accommodation is provided in a building, reasonable provision shall be made for the provision of suitable sanitary accommodation in any extension to the building.

     R5 Sanitary conveniences in dwellings
In a dwelling a sanitary convenience shall be provided—

     R6 Deemed-to-satisfy provisions for regulations R2, R3, R4 and R5


    (1) The requirements of regulation R2 shall be deemed to be satisfied, in the case of a building specified in column (2) of Table R opposite the reference to that regulation, if provision for access to and use of the building complies with the relevant provisions of the publications specified opposite thereto in column (3), as amended by the publications specified opposite thereto in column (4).

    (2) The requirements of regulation R3 shall be deemed to be satisfied, in the case of a building specified in column (2) of Table R opposite the reference to that regulation, if provision for access to an extension to the building complies with the relevant provisions of the publications specified opposite thereto in column (4).

    (3) The requirements of regulation R4 shall be deemed to be satisfied, in the case of a building specified in column (2) of Table R opposite the reference to that regulation, if the sanitary accommodation provided in an extension to the building complies with the relevant provisions of the publications specified opposite thereto in column (4).

    (4) The requirements of regulation R5 shall be deemed to be satisfied, in the case of a building specified in column (2) of Table R opposite the reference to that regulation, if the sanitary conveniences provided in the building comply with the relevant provisions of the publications specified opposite thereto in column (3), as amended by the publications specified opposite thereto in column (4).



SCHEDULE 4
Regulation 14(2)


Table to be substituted for Table F to Schedule 5 (Deemed-to-satisfy provisions) of the principal Regulations.



Table F (Conservation of fuel and power)
Regulations Buildings Publications Amendments
(1) (2) (3) (4)
F2

Conservation measures

any dwelling DFP Technical Booklet F1: 2006
           any other building DFP Technical Booklet F2: 2006
F3

Target carbon dioxide Emissions Rate

any dwelling The Government's Standard Assessment Procedure for energy rating of dwellings (SAP): 2005 edition
           any other building (a) The Simplified Building Energy Model (SBEM): 2006 edition;

                      (b) IES "Virtual Environment" software, version 5.5; or

                      (c) EDSL TAS software, version 9.0.9

F4

Provision of information

any dwelling DFP Technical Booklet F1: 2006
           any other building DFP Technical Booklet F2: 2006



SCHEDULE 5
Regulation 14(3)


Table to be substituted for Table H to Schedule 5 (Deemed-to-satisfy provisions) of the principal Regulations



Table H (Stairs, ramps, guarding and protection from impact)
Regulations Elements Publications Amendments
(1) (2) (3) (4)
H3

Stairs, ladders, ramps and landings

stair DFP Technical Booklet H: 2006: Sections 1 and 2
           ramp and landing DFP Technical Booklet H: 2006: Sections 1 and 3
           spiral or helical stair in a dwelling BS 5395: Part 2: 1984 AMD 6076
           ladder or stair# (a) BS 5395: Part 3: 1985; or

AMD 14247
                      (b) BS 4211: 2005

H4

Guarding

spiral or helical stair in a dwelling BS 5395: Part 2: 1984 AMD 6076
           ladder or stair# (a) BS 5395: Part 3: 1985; or

AMD 14247
                      (b) BS 4211: 1994

           vehicle barrier BS 6180: 1999 AMD 13292
           any other barrier DFP Technical Booklet H: 2006: Sections 1 and 4
H5

Vehicle loading bays

vehicle loading bay DFP Technical Booklet H: 2006: Section 5
H6

Protection against impact from and trapping by doors

door or gate DFP Technical Booklet H: 2006: Section 6
H7

Protection from collision with open windows, skylights or ventilators

open window, skylight or ventilator DFP Technical Booklet H: 2006: Section 7

Note—

# Providing access solely for the purpose of maintenance



SCHEDULE 6
Regulation 14(4)


Table to be substituted for Table L to Schedule 5 (Deemed-to-satisfy provisions) of the principal Regulations



Table L (Combustion appliances and fuel storage systems)
Part 1
Regulations Appliances Publications Amendments
(1) (2) (3) (4)
L2

Air supply

Solid fuel having a rated heat output up to 50 kW (a) DFP Technical Booklet L: 2006: Sections 0, 1 and 2; or

                      (b) BS 8303-1: 1994

           Gas having a rated heat input up to 70k W (nett) (a) DFP Technical Booklet L: 2006: Sections 0, 1 and 3; or

                      (b) BS 5440-2: 2000

AMD 13368

AMD 14912

           Oil having a rated heat output up to 45 kW (a) DFP Technical Booklet L: 2006: Sections 0, 1 and 4; or

                      (b) BS 5410-1: 1997

AMD 11022

AMD 13155

L3

Discharge of products of combustion

Solid fuel having a rated heat output up to 50 kW (a) DFP Technical Booklet L: 2006: Sections 0, 1 and 2; or

                      (b) BS 8303-1: 1994

           Gas having a rated heat input up to 70 kW (nett) (a) DFP Technical Booklet L: 2006: Sections 0, 1 and 3; or

                      (b) BS 5440-2: 2000

AMD 13368

AMD 14912

           Oil having a rated heat output up to 45 kW (a) DFP Technical Booklet L: 2006: Sections 0, 1 and 4; or

                      (b) BS 5410-1: 1997

AMD 11022

AMD 13155

L4

Protection of people and buildings

Solid fuel having a rated heat output up to 50 kW (a) DFP Technical Booklet L: 2006: Sections 0, 1 and 2; or

                      (b) BS 8303-1: 1994

           Gas having a rated heat input up to 70 kW (nett) (a) DFP Technical Booklet L: 2006: Sections 0, 1 and 3; or

                      (b) BS 5440-2: 2000

AMD 13368

AMD 14912

           Oil having a rated heat output up to 45 kW (a) DFP Technical Booklet L: 2006: Sections 0, 1 and 4; or

                      (b) BS 5410-1: 1997

AMD 11022

AMD 13155


Part 2
Regulations Aspects Publications Amendments
(1) (2) (3) (4)
L5

Provision of information

Technical information regarding the hearth, fireplace, flue and/or chimney DFP Technical Booklet L: 2006: Sections 0 and 1
L6

Protection of liquid fuel storage tanks

Gas (LPG) (a) DFP Technical Booklet L: 2006: Sections 0 and 5; or

                      (b) BS 5440-2: 2000

AMD 13368

AMD 14912

           Oil (a) DFP Technical Booklet L: 2006 Sections 0 and 5; or

                      (b) BS 5410-1: 1997

AMD 11022

AMD 13155

L7

Protection against pollution

Oil tank located above ground DFP Technical Booklet L: 2006: Sections 0 and 5



SCHEDULE 7
Regulation 14(5)


Table to be substituted for Table R to Schedule 5 (Deemed-to-satisfy provisions) of the principal Regulations



Table R
(Access to and use of buildings)
Regulations Buildings Publications Amendments
(1) (2) (3) (4)
R2

Access and use

a dwelling DFP Technical Booklet R: 2006: Sections 1, 7, 8 and 11
           a block of dwellings DFP Technical Booklet R: 2006: Sections 1, 7, 9 and 11
           any other building or part of a building DFP Technical Booklet R: 2006: Sections 1, 2, 3, 4, 5 and 6
R3

Access to extensions

any building other than a dwelling DFP Technical Booklet R: 2006: Sections 1, 2 and 3
R4

Sanitary accommodation in extensions

any building other than a dwelling DFP Technical Booklet R: 2006: Sections 1 and 6
R5

Sanitary conveniences in dwellings

a dwelling DFP Technical Booklet R: 2006: Sections 1 and 10



SCHEDULE 8
Regulation 14(6)


Table to be substituted for Table V to Schedule 5 (Deemed-to-satisfy provisions) of the principal Regulations



Table V
(Glazing)
Regulations Buildings Publications Amendments
(1) (2) (3) (4)
V2

Impact with glazing

any building DFP Technical Booklet V: 2000: Sections 1 and 2 AMD 3
V3

Transparent glazing

any building other than a dwelling DFP Technical Booklet V: 2000: Section 3 AMD 3
V4

Safe opening and closing of windows, skylights and ventilators

any building DFP Technical Booklet V: 2000: Section 4 AMD 3
V5

Safe means of access for cleaning glazing

any building DFP Technical Booklet V: 2000: Section 5 AMD 3



EXPLANATORY NOTE

(This note is not part of the Regulations)


These Regulations amend the Building Regulations (Northern Ireland) 2000 (the principal Regulations). They do not apply to building work which has been completed, or for which plans or building notices have been deposited with a district council before the commencement of these Regulations.

The changes to the principal Regulations are as follows—

     1. Part F has been replaced. New regulations to raise energy performance standards have been introduced and compliance will be measured against an overall emissions target. For the first time, buildings over 1000 m² undergoing major refurbishment will have to be upgraded to comply with the energy performance requirements.

     2. Part L has been replaced and renamed "Combustion appliances and fuel storage systems" to become more inclusive of solid fuel, oil and gas fired appliances and the storage of their associated fuel. New regulations for the provision of information, the protection of liquid fuel storage tanks and the protection against pollution have also been introduced and all references to the deemed-to-satisfy documents for Part L have been updated.

     3. Part R has been replaced and renamed "Access to and use of buildings". The amendment is only in relation to buildings other than dwellings with the introduction of new regulations for access to extensions and sanitary accommodation in extensions.

     4. New tables have been substituted for Tables F, H, L, R and V of Schedule 5 so that updated deemed-to-satisfy references are inserted.

     5. Consequential amendments have been made to Part A.

     6. Minor amendments have been made to Parts B and V and to Table E of Schedule 5.

Regulatory Impact Assessments have been prepared. Copies can be obtained on request from the Building Standards Branch, Department of Finance and Personnel, 10th Floor River House, 48 High Street, Belfast BT1 2AW. Alternatively, they can be downloaded from
www.buildingregulationsni.gov.uk.

These Regulations were notified in draft to the European Commission in accordance with Directive 98/34/EC, as amended by Directive 98/48/EC.


Notes:

[1] S.I. 1979/1709 (N.I.16); Article 5(1) as amended by S.I. 1990/1510 (N.I.14), Article 38 (1) and Sch. 1, Part IIback

[2] See S.R. 1999 No. 481 Art. 6 and Sch. 4, Part IIback

[3] S.I. 1979/1709 (N.I.16); Article 5(4)back

[4] S.R. 2000 No. 389, as amended by S.R. 2005 No. 295back

[5] S.I. 1981 No. 158 (N.I. 4)back

[6] S.I. 1981 No. 158 (N.I. 4)back



ISBN 0 337 96626 5


 © Crown copyright 2006

Prepared 5 September 2006